新闻资讯

新闻资讯

current position: Home > News Center > Frequently Asked Question

How to minimize the splashing of the gate?

2024-06-07 17:27:08
times

How to minimize the splashing of the gate?
In order to reduce the splashing of the gate, we need to comprehensively consider multiple aspects such as the selection, installation, operation, and maintenance of the gate blowout preventer. The following will elaborate on how to effectively reduce gate splashing:
1、 Selection and installation of gate blowout preventer
Selection of appropriate ram blowout preventer: select the appropriate type of ram blowout preventer according to the operating environment and needs, such as spray suppression ram blowout preventer, elastic blowout preventer or sliding blowout preventer. These blowout preventers have their own characteristics, such as spray suppression ram blowout preventers, which can effectively reduce water flow splash.
Installation of gate blowout preventer: When installing the gate blowout preventer, ensure that all components are tightly connected and installed correctly. For example, before installation, the size of the gate should be checked to ensure that it matches the size of the pipe column used, to ensure that each control gate is flexible and reliable, and that the manifold pressure gauge is within the calibration period. During the installation process, precautions should be taken to prevent damage to the steel ring, and a steel ring guard plate should be used to protect the pipe column. At the same time, after installation, a comprehensive inspection of the gate blowout preventer should be conducted to ensure that there are no leaks.

2、 Operation and maintenance of gate blowout preventer
Standardize the operation of the gate anti spray device: During the operation process, it should be strictly carried out in accordance with the operating procedures to avoid splashing caused by misoperation. For example, when opening and closing the gate, the control manifold oil pressure should be released first to prevent damage to the "O" ring of the hinge shaft. At the same time, it is strictly prohibited to release the pressure inside the well by opening the gate. Before each opening of the gate, check whether the manual locking device is unlocked, and after opening, check whether the gate is fully open and retracted into the casing.
Regular maintenance of the gate blowout preventer: Regular maintenance and upkeep of the gate blowout preventer can ensure its long-term stable operation and reduce splashing. The maintenance includes checking whether the connection parts are tightened, whether the sealing performance is good, and whether the operating rod is flexible. At the same time, severely worn components such as sealing rings and gate plates should be replaced in a timely manner.
3、 Other measures to reduce splashing
Optimizing the process flow: By optimizing the process flow, unnecessary fluid flow and pressure changes are reduced, thereby reducing splashing phenomena. For example, in drilling operations, drilling parameters and mud properties can be set reasonably to reduce pressure fluctuations inside the well.
Using auxiliary equipment: Installing auxiliary equipment such as baffles and guide grooves around the gate blowout preventer can further reduce splashing. These devices can effectively collect and discharge splashing fluids, reducing the impact on the surrounding environment and equipment.
4、 Summary and Induction
Reducing gate splashing requires comprehensive consideration and implementation of measures from multiple aspects. Measures such as selecting appropriate gate spray preventers, installation, standardized operation, regular maintenance, optimizing process flow, and using auxiliary equipment can effectively reduce splashing phenomena. By implementing these measures, we can provide a safer and more environmentally friendly working environment for drilling operations. At the same time, we should also continue to pay attention to the development of new technologies and equipment, continuously improve the performance of gate preventers and their ability to reduce splashing phenomena.

Tags

Recently Viewed:

  • menu

Contact

Address: No. 806 Nanhuan Road, Jianhu County, Yancheng City, Jiangsu Province
Contact: Xiao Guangtian, Customer Business Department, 13891863198 (same WeChat account)
Sales Director Zhang Baomin 13505469793 (same WeChat account)
Technical Director Xia Zhenghua 13605106962 (same WeChat account)
Phone: 0515-86250666
Fax: 0515-86250555

Email: ycsz@ycszsy.com